GNETINJE
Recognised by the OPM Flow parserSCHEDULE
The GNETINJE keyword defines the configuration of a group injection network for when the either the Standard Network or the Extended Network options have been activated. The Standard Network option is invoked if the GRUPTREE, GRUPNET, GNETINJE, GNETPUMP, etc. series of keywords have been used in the SCHEDULE section. Whereas, the Extended Network option is activated by the NETWORK keyword in the RUNSPEC section. Several keywords, including, GNETINJE, can be used by both network options.
This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.
- Records
- One or more records, each terminated by
/ - Items per record
- 4
Parameters
| No. | Name | Description | Type | Dimension | Default |
|---|---|---|---|---|---|
| 1 | GROUP | STRING | |||
| 2 | PHASE | STRING | |||
| 3 | PRESSURE | DOUBLE | Pressure | ||
| 4 | VFP_ | INT | 0 |
Manual source: parts/chapters/subsections/12.3/GNETINJE.fodt