GNETDP

Recognised by the OPM Flow parserSCHEDULE

The GNETDP keyword sets a group’s minimum and maximum network pressure and rate controls for when the either the Standard Network or the Extended Network options have been activated, and the group is part of a network. The keywords allows for the pressure of the group to vary in order to satisfy the rate conditions declared by this keyword. The Standard Network option is invoked if the GRUPTREE, GRUPNET, GNETINJE, GNETPUMP, etc. series of keywords have been used in the SCHEDULE section. Whereas, the Extended Network option is activated by the NETWORK keyword in the RUNSPEC section. Several keywords, including, GNETDP, can be used by both network options.

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
One or more records, each terminated by /
Items per record
8

Parameters

No.NameDescriptionTypeDimensionDefault
1FIXED_PRESSURE_GROUPSTRING
2PHASE_TYPESTRINGGA
3MIN_RATE_TRIGGERDOUBLE0
4MAX_RATE_TRIGGERDOUBLE1e+20
5PRESSURE_INCR_SUBTRACTDOUBLEPressure0
6PRESSURE_INCR_ADDDOUBLEPressure0
7MIN_ALLOW_PRESSUREDOUBLEPressure0
8MAX_ALLOW_PRESSUREDOUBLEPressure1e+20

Manual source: parts/chapters/subsections/12.3/GNETDP.fodt