WTHPMAX

Recognised by the OPM Flow parserSCHEDULE

WTHPMAX stipulates a well’s maximum flowing Tubing Head Pressure (“THP”), above which the well will be shut-in. The facility is useful if the THP exceeds the wellhead maximum design pressure, which can occur if excessive gas invades the wellbore. In addition to setting the maximum THP, the keyword defines the criteria for re-testing the well to see if the THP has fallen below the maximum value.

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
One or more records, each terminated by /
Items per record
5

Parameters

No.NameDescriptionTypeDimensionDefault
1WELLSTRING
2MAX_THP_DESIGN_LIMITDOUBLEPressure
3CONTROLSTRINGORAT
4CONTROL_LIMITDOUBLE
5THP_OPEN_LIMITDOUBLEPressure

Manual source: parts/chapters/subsections/12.3/WTHPMAX.fodt