WSEGTABL

Recognised by the OPM Flow parserSCHEDULE

WSEGTABL assigns previously defined Vertical Lift Performance (“VLP”) tables as specified by the VFPPROD keyword in the SCHEDULE section, to multi-segment well segments, as well as stipulating how the tables are to be applied.

The FLOWOPT parameter on the WELSEGS keyword in the SCHEDULE section sets the default multi-segment well model. FLOWOPT either activates the homogeneous model, that is all phases flow at the same velocity, or the Drift Flux Slip model. However, the WSEGFMOD keyword in the SCHEDULE section, can be used to set the flow model for a segment to either the homogeneous model or the Drift Flux Slip model, and addition a: VLP table allocated via the WSEGTABL keyword, or a specific model as defined by the WSEGVALV, WSEGFLIM and WSEGLABY keywords.

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
One or more records, each terminated by /
Items per record
9

Parameters

No.NameDescriptionTypeDefault
1WELLSTRING
2SEGMENT1INT
3SEGMENT2INT
4VFPINT0
5VFP_COMPONENTSSTRINGFH
6VFP_OUTLIERSTRING
7DP_SCALINGSTRINGLEN
8ALQ_VALUEDOUBLE0
9STATUSSTRINGOPEN