WSEGINIT

Recognised by the OPM Flow parserSCHEDULE

Normally the simulator calculates the initial conditions for multi-segment wells, that is the pressure and fluid distributions in each segment. However, there are occasions when manually setting the pressures and phase distributions for each segment to investigate certain flow conditions may be useful. In this case the WSEGINIT keyword may be used to specify the initial conditions manually. Note that segments not initialized by this keyword will be automatically initialized by the simulator

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
One or more records, each terminated by /
Items per record
11

Parameters

No.NameDescriptionTypeDimension
1WELLSTRING
2SEGMENT1INT
3SEGMENT2INT
4P0DOUBLEPressure
5W0DOUBLE
6G0DOUBLE
7RSDOUBLE
8RVDOUBLE
9APIDOUBLE
10POLYMERDOUBLEConcentration
11BRINEDOUBLEConcentration

Manual source: parts/chapters/subsections/12.3/WSEGINIT.fodt