WSEGDFPA

Recognised by the OPM Flow parserSCHEDULE

This keyword, WSEGDFPA, enables modification of a multi-segment well’s drift flux slip model default parameters used by the WSEGDFMA keyword in the SCHEDULE section to define the model. A slip model337 Shi, H., Holmes, J.A., Durlofsky, L. J., Aziz, K., Diaz, L. R., Alkaya, B., and Oddie, G. “Drift-Flux Modeling of Two-Phase Flow in Wellbores,” paper SPE 84228, Society of Petroleum Engineers Journal (2005) 10, No. 1, 24-33; also presented as “Drift-Flux Modeling of Multiphase Flow in Wellbores,” at the SPE Annual Technical Conference and Exhibition, Denver, Colorado, USA(October 5-8, 2003). and 338 Shi, H., Holmes, J.A., Diaz, L. R., Durlofsky, L. J., and Aziz, K. “Drift-Flux Parameters for Three-Phase Steady-State Flow in Wellbores,” paper SPE 89836, Society of Petroleum Engineers Journal(2005) 10, No. 2, 130-137; also presented at the SPE Annual Technical Conference and Exhibition, Houston, Texas, USA (September 26-29, 2004).enables the different phases in the wellbore to flow at different velocities, for example gas will flow up the tubing at a higher velocity than oil and water. The option is activated by the FLOWOPT parameter on the WELSEGS keyword in the SCHEDULE section; however, the slip model flow calculation is not available in OPM Flow.

Shi, H., Holmes, J.A., Durlofsky, L. J., Aziz, K., Diaz, L. R., Alkaya, B., and Oddie, G. “Drift-Flux Modeling of Two-Phase Flow in Wellbores,” paper SPE 84228, Society of Petroleum Engineers Journal (2005) 10, No. 1, 24-33; also presented as “Drift-Flux Modeling of Multiphase Flow in Wellbores,” at the SPE Annual Technical Conference and Exhibition, Denver, Colorado, USA(October 5-8, 2003).

Shi, H., Holmes, J.A., Diaz, L. R., Durlofsky, L. J., and Aziz, K. “Drift-Flux Parameters for Three-Phase Steady-State Flow in Wellbores,” paper SPE 89836, Society of Petroleum Engineers Journal(2005) 10, No. 2, 130-137; also presented at the SPE Annual Technical Conference and Exhibition, Houston, Texas, USA (September 26-29, 2004).

See also the WSEGDFIN keyword that sets the slip model’s input parameters and the WSEGDFMD keyword that sets which drift flux slip model should be used. Note if the WSEGDFPA keyword is used than it must be placed after the WSEGDFMD keyword, but before the WELSEGS keyword that defines a multi-segment well. All the aforementioned keywords are in the SCHEDULE section.

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
Fixed number of records
Record count
1
Items per record
11

Parameters

No.NameDescriptionTypeDefault
1GAS_LIQUID_VD_FACTORDOUBLE1
2A1DOUBLE
3A2DOUBLE
4C0_ADOUBLE1.2
5C0_BDOUBLE
6FVDOUBLE1
7OIL_WATER_VD_FACTORDOUBLE-1
8ADOUBLE
9B1DOUBLE
10B2DOUBLE
11NDOUBLE

Manual source: parts/chapters/subsections/12.3/WSEGDFPA.fodt