WREGROUP

Recognised by the OPM Flow parserSCHEDULE

WREGROUP defines the criteria to automatically re-assign wells to various other groups. This can be used, for example, to move wells on THP control flowing through a high pressure separator group to a low pressure separator group in order for the wells to be under different group controls for low pressure wells.

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
One or more records, each terminated by /
Items per record
6

Parameters

No.NameDescriptionTypeDefault
1WELLSTRING
2QUANTITYSTRING
3GROUP_UPPERSTRING
4UPPER_LIMITDOUBLE1e+20
5GROUP_LOWERSTRING
6LOWER_LIMITDOUBLE0

Manual source: parts/chapters/subsections/12.3/WREGROUP.fodt