VFPPDIMS

Recognised by the OPM Flow parserRUNSPEC

VFPPDIMS keyword defines the maximum dimensions of the production well Vertical Lift Performance (“VFP”) tables defined by VFPPROD keyword. The VFP tables for the injection wells are defined by the VFPIDIMS keyword.

Notes:

The keyword is terminated by a “/”.

Records
Fixed number of records
Record count
1
Items per record
6

Parameters

No.NameDescriptionTypeDefault
1MAX_FLOW_TABLE
manual: MXMFLO
A positive integer that defines the maximum number of production flow rate entries for the VFPPROD keyword.INT0
2MAX_THP_TABLE
manual: MXMTHP
A positive integer that defines the maximum number of THP entries for the VFPPROD keyword.INT0
3MAX_WCT_TABLE
manual: MXMWFR
A positive integer that defines the maximum number of water fraction entries (WOR, WCUT, GWR etc.) for the VFPPROD keyword.INT0
4MAX_GCT_TABLE
manual: MXMGFR
A positive integer that defines the maximum number of gas fraction entries (GOR, GLR, OGR etc.) for the VFPPROD keyword.INT0
5MAX_ALQ_TABLE
manual: MXMALQ
A positive integer that defines the maximum number of artificial lift quantity entries for the VFPPROD keyword.INT0
6MAX_PROD_VFP_TABLE
manual: MXVFPTAB
A positive integer that defines the maximum number of VFPPROD tables entered through the VFPPROD keyword.INT0

Example

-- PRODUCING VFP TABLES
-- VFP VFP VFP VFP VFP VFP
-- MXMFLO MXMTHP MXMWFR MXMGFR MXMALQ NMMVFT
VFPPDIMS
20 10 10 10 6 9 /
Here the example shows that there are a maximum of 20 flow rates, 10 THP entries, 10 water and gas fraction entries, and six artificial lift entries for the nine VFPPROD VFP production tables.

Manual source: parts/chapters/subsections/5.3/VFPPDIMS.fodt