SOXYG

Recognised by the OPM Flow parserSOLUTION

The SOXYG keyword defines the initial equilibration oxygen concentration values for all grid cells in the model. The keyword should only be used if the MICP model has been activated in the RUNSPEC section.

Note

This is an OPM Flow specific keyword.

Notes:

The number of entries should correspond to the NX x NY x NZ parameters on the DIMENS keyword in the RUNSPEC section, unless the BOX keyword defines a sub area of the grid, in which case the total number of entries should correspond to the number of cells defined by the BOX statement.

The keyword is terminated by a “/”.

See also the SBIOF, SCALC, SMICR, and SUREA keywords to define the initial state of the model.

Records
An array of values covering the grid

Parameters

No.NameDescriptionFieldMetricLabDefault
1SOXYGSOXYG is an array of real numbers that are greater than or equal to zero assigning the initial equilibration oxygen concentration values to each cell in the model. Repeat counts may be used, for example 20*0.1500lb/stbkg/sm3gm/sccNone

Example

--
-- DEFINE INITIAL EQUILIBRATION OXYGEN CONCENTRATION FOR ALL CELLS
-- BASED ON NX = 100, NY = 100 AND NZ = 3
--
SOXYG
1000*0.0000 1000*0.0000 1000*0.1500 /
The above example defines the initial equilibration oxygen concentration values to be 0.0000 for all the cells in the first and second layers and finally 0.1500 for all the cells in the third layer.
| Note This is an OPM Flow specific keyword. |
|--------------------------------------------|

Related keywords

Requires
MICP, WATER

Manual source: parts/chapters/subsections/10.3/SOXYG.fodt