SOWCR

Recognised by the OPM Flow parserPROPS

Part of the ENDPOINT_SPECIFIERS keyword family in the OPM Flow parser.

SOWCR defines the critical oil saturation for all the cells in the model via an array when the end-point scaling option has been invoked via the ENDSCALE keyword in the RUNSPEC section. The critical oil saturation with respect to water is defined as the maximum oil saturation for which the oil relative permeability is zero in a two-phase oil-water relative permeability table.

The keyword can be used with all grid types.

Notes:

Note this the directional independent version of the critical gas saturation used with the end-point scaling option. If directional end-point scaling has been activated then the SOWCRX± , SOWCRY± and SOWCRZ± series of keyword should be used.

If the value for a cell has been defaulted then OPM Flow uses the value from the cell’s relative permeability table.

The keyword is terminated by a “/”.

End-point scaling allows the entered relative permeability functions to be re-scaled based on the saturation end-points allocated to each cell by the SWL, SWCR, SWU, SGL, SGCR, SGU, SOWCR, and SOGCR saturation grid arrays for the saturation end-points, and the KRG, KRGR, KRO, KRORG, KRORW, KRW and KRWR relative permeability grid cell arrays for the relative permeability end-point data. In addition end-point scaling may be directional dependent in which case the directional dependent versions of the aforementioned arrays should be used, that is SOWCRX, SOWCRY and SOWCRZ instead of SOWCR. There is also the facility to make the directional end-point scaling reversible or non-reversible and if the non-reversible option is selected the non-reversible versions of the aforementioned arrays should be used, that is SOWCRX, SOWCRX-, SOWCRY, SOWCRY-, SOWCRZ and SOWCRZ-, instead of the SOWCR keyword.

Records
An array of values covering the grid

Parameters

No.NameDescriptionFieldMetricLabDefault
1SOWCRSOWCR is an array of real numbers assigning the critical oil saturation with respect to water values to each cell in the model. The number of entries should correspond to the NX x NY x NZ parameters on the DIMENS keyword. Repeat counts may be used, for example 30*0.30dimensionlessdimensionlessdimensionlessTaken from cell allocated relative permeability table.

Example

--
-- DEFINE GRID BLOCK END-POINT SOWCR DATA FOR ALL CELLS
– (FOR NX x NY x NZ = 300)
--
SOWCR
300*0.200 /
The above example defines a constant critical oil saturation of 0.20 to all 300 cells in the model as defined by the DIMENS keyword in the RUNSPEC section.

Related keywords

Requires
OIL, WATER, ENDSCALE

Manual source: parts/chapters/subsections/8.3/SOWCR.fodt