SKIP300
Recognised by the OPM Flow parserRUNSPECGRIDEDITPROPSREGIONSSOLUTIONSUMMARYSCHEDULE
Variant 1 — RUNSPEC section
The SKIP300 keyword activates skipping of all keywords and input data by the commercial compositional simulator until the ENDSKIP keyword is encountered. All keywords between the SKIP300 and ENDSKIP keywords are ignored by the commercial compositional simulator. The SKIP300 keyword is ignored by the commercial black-oil simulator.
See Error: Reference source not foundin the GLOBAL section for a full description.
- Records
- No records — the keyword stands alone
Manual source: parts/chapters/subsections/5.3/SKIP300.fodt
Variant 2 — GRID section
The SKIP300 keyword activates skipping of all keywords and input data by the commercial compositional simulator until the ENDSKIP keyword is encountered. All keywords between the SKIP300 and ENDSKIP keywords are ignored by the commercial compositional simulator. The SKIP300 keyword is ignored by the commercial black-oil simulator.
See Error: Reference source not foundin the GLOBAL section for a full description.
- Records
- No records — the keyword stands alone
Manual source: parts/chapters/subsections/6.3/SKIP300.fodt
Variant 3 — EDIT section
The SKIP300 keyword activates skipping of all keywords and input data by the commercial compositional simulator until the ENDSKIP keyword is encountered. All keywords between the SKIP300 and ENDSKIP keywords are ignored by the commercial compositional simulator. The SKIP300 keyword is ignored by the commercial black-oil simulator.
See Error: Reference source not foundin the GLOBAL section for a full description.
- Records
- No records — the keyword stands alone
Manual source: parts/chapters/subsections/7.3/SKIP300.fodt
Variant 4 — PROPS section
The SKIP300 keyword activates skipping of all keywords and input data by the commercial compositional simulator until the ENDSKIP keyword is encountered. All keywords between the SKIP300 and ENDSKIP keywords are ignored by the commercial compositional simulator. The SKIP300 keyword is ignored by the commercial black-oil simulator.
See Error: Reference source not foundin the GLOBAL section for a full description.
- Records
- No records — the keyword stands alone
Manual source: parts/chapters/subsections/8.3/SKIP300.fodt
Variant 5 — REGIONS section
The SKIP300 keyword activates skipping of all keywords and input data by the commercial compositional simulator until the ENDSKIP keyword is encountered. All keywords between the SKIP300 and ENDSKIP keywords are ignored by the commercial compositional simulator. The SKIP300 keyword is ignored by the commercial black-oil simulator.
See Error: Reference source not foundin the GLOBAL section for a full description.
- Records
- No records — the keyword stands alone
Manual source: parts/chapters/subsections/9.3/SKIP300.fodt
Variant 6 — SOLUTION section
The SKIP300 keyword activates skipping of all keywords and input data by the commercial compositional simulator until the ENDSKIP keyword is encountered. All keywords between the SKIP300 and ENDSKIP keywords are ignored by the commercial compositional simulator. The SKIP300 keyword is ignored by the commercial black-oil simulator.
See Error: Reference source not foundin the GLOBAL section for a full description.
- Records
- No records — the keyword stands alone
Manual source: parts/chapters/subsections/10.3/SKIP300.fodt
Variant 7 — SUMMARY section
Turns on skipping of “compositional” keywords until the ENDSKIP activation keyword is encountered. All “compositional” keywords between the SKIP300 and ENDSKIP keywords are ignored by OPM Flow.
See Error: Reference source not foundin the GLOBAL section for a full description.
- Records
- No records — the keyword stands alone
Manual source: parts/chapters/subsections/11.3/SKIP300.fodt
Variant 8 — SCHEDULE section
The SKIP300 keyword activates skipping of all keywords and input data by the commercial compositional simulator until the ENDSKIP keyword is encountered. All keywords between the SKIP300 and ENDSKIP keywords are ignored by the commercial compositional simulator. The SKIP300 keyword is ignored by the commercial black-oil simulator.
See Error: Reference source not foundin the GLOBAL section for a full description.
- Records
- No records — the keyword stands alone
Manual source: parts/chapters/subsections/12.3/SKIP300.fodt