SIGMAV

Recognised by the OPM Flow parserGRID

The SIGMAV keyword defines a dual porosity matrix to fracture multiplier, sigma, that is applied to individual cells, for when the Dual Porosity model has been invoked by either the DUALPORO or the DUALPERM keywords in the RUNSPEC section. Sigma (σ) takes into account the matrix-fracture interface area per unit volume and was defined by Kazemi et al129 Kazemi, H., Merrill JR., L. S., Porterfield, K. L., and Zeman, P. R. “Numerical Simulation of Water-Oil Flow in Naturally Fractured Reservoirs,” paper SPE 5719, Society of Petroleum Engineers Journal (1976) 16, No. 6, 317-326. to be:

Kazemi, H., Merrill JR., L. S., Porterfield, K. L., and Zeman, P. R. “Numerical Simulation of Water-Oil Flow in Naturally Fractured Reservoirs,” paper SPE 5719, Society of Petroleum Engineers Journal (1976) 16, No. 6, 317-326.

[%sigma `=` 4left(1 over {l sub x} sup 2` + 1 over {l sub y} sup 2`+ 1 over {l sub z} sup 2` right)]

(6.18)

Where lx, ly and lz are not the grid block dimensions in the model in the respective directions, but the dimensions of the blocks of the matrix material. In practice, σ is used as a tuning parameter in dual porosity runs to match reservoir and well performance.

See also the SIGMA keyword in the GRID section that supplies a constant sigma to all cells.

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
An array of values covering the grid

Example

| [%sigma `=` 4left(1 over {l sub x} sup 2` + 1 over {l sub y} sup 2`+ 1 over {l sub z} sup 2` right)] | (6.18) |
|------------------------------------------------------------------------------------------------------|--------|

Manual source: parts/chapters/subsections/6.3/SIGMAV.fodt