PIMTDIMS

Recognised by the OPM Flow parserRUNSPEC

PIMTDIMS keyword defines the maximum number of PIMULTAB tables and the maximum number of entries (or rows) per PIMULTAB table. The PIMULTAB keyword is used to define a well’s productivity index factor as a function of a well’s producing water cut.

Notes:

The keyword is terminated by a “/”.

Records
Fixed number of records
Record count
1
Items per record
2

Parameters

No.NameDescriptionTypeDefault
1NTPIMTA positive integer value that defines the maximum number of PIMULTAB keywords defined in the input deck.INT0
2NPPIMT
manual: NRPIMT
A positive integer value defining the maximum number of entries (rows) in the PIMULTAB keyword.INT0

Example

--
-- MAX MAX
-- TABLES ENTRIES
PIMTDIMS
1 51 /
The above example defines that there is one PIMULTAB table with a maximum number of 51 rows.

Manual source: parts/chapters/subsections/5.3/PIMTDIMS.fodt