NOCASC

Recognised by the OPM Flow parserRUNSPEC

NOCASC keyword activates the linear solver tracer algorithm for single phase tracers.

OPM Flow uses a different numerical scheme which makes this keyword redundant; hence, OPM Flow ignores this keyword. It is documented here for completeness.

There is no data required for this keyword and there is no terminating “/” for this keyword.

Records
No records — the keyword stands alone

Example

--
-- TRACER SOLVER OPTION
--
NOCASC
The above example switches on the linear solver tracer algorithm; however, this has no effect in OPM Flow input decks.

Manual source: parts/chapters/subsections/5.3/NOCASC.fodt