NCOMPS

Recognised by the OPM Flow parserPROPS

This keyword confirms the maximum number of compositional components in the model, as such it should have the same number of components as that declared via the COMPS keyword in the RUNSPEC section. The keyword should only be used if the CO2STORE keyword and either the GASWAT or the GAS and WATER keywords in the RUNSPEC section, have also be activated for the gas-water two component model.

Note

This is an OPM Flow keyword used with OPM Flow’s CO2STORE and GASWAT keywords in the RUNSPEC section, and should not be confused with the more general version of the NCOMPS keyword used in the commercial compositional simulator.

Secondly, although OPM Flow parses the keyword, the simulator currently ignores the data for this keyword.

Notes:

The keyword is terminated by a “/”.

Records
Fixed number of records
Record count
1
Items per record
1

Parameters

No.NameDescriptionTypeDefault
1NUM_COMPS
manual: NCOMPS
A positive integer defining the maximum number of compositional components in the model. Secondly the number of components must be the same as that enter via the COMPS keyword in the RUNSPEC section. Only the default value of two is currently supported by OPM Flow.INT2

Example

The following example defines how to confirm a two component formulation to be used with the CO2STORE and GASWAT options.
--
-- CONFIRM NUMBER OF COMPOSITIONAL COMPONENTS (OPM FLOW KEYWORD)
--
NCOMPS
2 /
| Note This is an OPM Flow keyword used with OPM Flow’s CO2STORE and GASWAT keywords in the RUNSPEC section, and should not be confused with the more general version of the NCOMPS keyword used in the commercial compositional simulator. Secondly, although OPM Flow parses the keyword, the simulator currently ignores the data for this keyword. |
|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|

Manual source: parts/chapters/subsections/8.3/NCOMPS.fodt