MISCIBLE

Recognised by the OPM Flow parserRUNSPEC

The MISCIBLE keyword defines the options associated with the Todd-Longstaff91 M. R. Todd and W. J Longstaff, The Development, Testing, and Application Of a Numerical Simulator for Predicting Miscible Flood Performance". In: J. Petrol. Tech. 24.7 (1972), pages 874-882. mixing parameters used for when polymer flooding or CO2 EOR simulation cases are being run.

M. R. Todd and W. J Longstaff, The Development, Testing, and Application Of a Numerical Simulator for Predicting Miscible Flood Performance". In: J. Petrol. Tech. 24.7 (1972), pages 874-882.

Notes:

The keyword is terminated by a “/”.

Records
Fixed number of records
Record count
1
Items per record
3

Parameters

No.NameDescriptionTypeDefault
1NTMISCA positive integer value that declares the number miscible residual oil saturations versus water saturations tables for SORWMIS keyword and the number Todd-Longstaff mixing parameters entries on the TLMIXPAR keyword.INT1
2NSMISCA positive integer value that sets the maximum number of entries (or rows) for each SORWMIS table defined by the SORWMIS keyword.INT20
3TWOPOINT
manual: MISOPT
A character string that defines the numerical dispersion control options for the oil and gas relative permeability curves, set to either NONE or TWOPOINT: NONE – standard single point up streaming, that is using the immediate neighbor TWOPOINT – two-point up streaming, that is using the immediate neighbor plus one cell for better numerical dispersion control but with a higher computational cost. Only the default value of NONE is supported.STRINGNONE

Example

--
-- NTAB MAX UPSTRM
-- NTMISC NSMISC MISOPT
MISCIBLE
1 20 NONE /
The above example defines the default values for the MISCIBLE keyword, that is one table with a maximum of 20 rows per table using the standard one cell upstream option.

Manual source: parts/chapters/subsections/5.3/MISCIBLE.fodt