LYFIN

Recognised by the OPM Flow parserGRID

The LYFIN keyword defines the parameters for automatically generating a Local Grid Refinement (“LGR”) grid in the Y direction based on logarithmic block spacing, for when the LGR option has been activated by the LGR keyword in the RUNSPEC section. LYFIN should be placed in between the CARFIN and ENDFIN keywords in the GRID section.

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
Fixed number of records
Record count
1
Items per record
2

Parameters

No.NameDescriptionTypeDimension
1CELL_THICKNESSDOUBLELength
2SIZE_OPTIONSTRING

Manual source: parts/chapters/subsections/6.3/LYFIN.fodt