IMKRVD
Recognised by the OPM Flow parserPROPS
This keyword defines the maximum imbibition oil, gas, and water relative permeability versus depth for the three phases. The ENDSCALE keyword in the RUNSPEC section should be activated to enable end-point scaling and the use of this keyword. In addition, the HYSTER option on the SATOPTS keyword in the RUNSPEC section has to be activated to invoke the Hysteresis option.
This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.
- Records
- Fixed number of records
- Variadic
- The record accepts a variable number of items
Parameters
| No. | Name | Description | Type | Dimension |
|---|---|---|---|---|
| 1 | DATA | DOUBLE | Length, 1, 1, 1, 1, 1, 1, 1 |
Manual source: parts/chapters/subsections/8.3/IMKRVD.fodt