GUPFREQ

Recognised by the OPM Flow parserSCHEDULE

The GUPFREQ keyword sets the update frequency of the Instantaneous Gradient option for when this option has been activated by the GDIMS keyword in the RUNSPEC section. The Instantaneous Gradient option calculates derivatives of solution quantities at the current time step with respect to variations in the variables at the current time step. This is different to Gradient option that calculates the derivatives of solution quantities at the current time step with respect to variations in the variables at the initial time step, that is a time equal to zero. Consequently, the Instantaneous Gradient option can be switched on and off by the GUPFREQ keyword in the SCHEDULE section, whereas the Gradient option cannot.

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
Fixed number of records
Record count
1
Items per record
1

Parameters

No.NameDescriptionTypeDefault
1UPDATE_FREQ_TYPESTRINGALL

Manual source: parts/chapters/subsections/12.3/GUPFREQ.fodt