GSF

Recognised by the OPM Flow parserPROPS

The GSF keyword defines the gas relative permeability and gas-water capillary pressure data versus gas saturation tables for when only gas and water are present in the input deck. This keyword should only be used if the gas and water phases are present in the run, and can therefore also be used with the CO2STORE and H2STORE models. In addition, the keyword must be used in conjunction with the WSF keyword in the PROPS section, that defines the water relative permeability versus water saturation for gas-water systems.

Note

GSF is a compositional keyword in the commercial compositional simulator, and will therefore cause an error in the commercial black-oil simulator.

Currently, both the GSF and WSF keywords can only be used with the CO2STORE and H2STORE models.

Notes:

The keyword is followed by NTSFUN tables as declared on the TABDIMS keyword in the RUNSPEC section.

Each table must contain a minimum of two rows and a maximum of NSSFUN rows as declared on the TABDIMS keyword in the RUNSPEC section.

Each table is terminated by a “/” and there is no “/” terminator for the keyword.

See also the WSF - Water Saturation Tables versus Water Saturation (Gas-Water and CO2STORE Systems)keyword in the PROPS section, that defines the water saturation as a function of water saturation for when only the gas and water phases are present in the model.

Records
Fixed number of records
Variadic
The record accepts a variable number of items

Parameters

No.NameDescriptionTypeDimensionFieldMetricLabDefault
1DATA
manual: SGAS
A columnar vector of real values monotonically increasing down the column starting from zero and terminating at one minus the connate water saturation, that defines the gas saturation.DOUBLE1, 1, PressuredimensionlessdimensionlessdimensionlessNone
2KRGA columnar vector of real values that are either equal or increasing down the column and that are greater than or equal to zero and less than or equal to one that defines the gas relative permeability. Note that the first entry in the column must be zero.dimensionlessdimensionlessdimensionlessNone
3PCWGA columnar vector of real values that are either equal or increasing down the column that defines the gas-water capillary pressure.psiabarsatmNone

Example

--
-- GAS RELATIVE PERMEABILITY TABLES (OPM FLOW KEYWORD)
--
GSF
-- SGAS KRG PCGW
-- FRAC PSIA
-- -------- -------- -------
0.00 0.0000 0.0
0.05 0.0000 0.0
0.10 0.0000 0.0
0.15 0.0000 0.0
0.20 0.0002 0.0
0.25 0.0010 0.0
0.30 0.0062 0.0
0.35 0.0140 0.0
0.40 0.0273 0.0
0.45 0.0450 0.0
0.50 0.0707 0.0
0.55 0.1020 0.0
0.60 0.1412 0.0
0.65 0.1870 0.0
0.70 0.2412 0.0
0.77 0.3288 0.0
0.82 0.4000 0.0
0.85 0.4450 0.0 / TABLE NO. 01
-- SGAS KRG PCGW
-- FRAC PSIA
-- -------- -------- -------
0.00 0.0000 0.0
0.05 0.0000 0.0
0.10 0.0000 0.0
0.15 0.0000 0.0
0.20 0.0002 0.0
0.25 0.0010 0.0
0.30 0.0062 0.0
0.35 0.0140 0.0
0.40 0.0273 0.0
0.45 0.0450 0.0
0.50 0.0707 0.0
0.55 0.1020 0.0
0.60 0.1412 0.0
0.65 0.1870 0.0
0.70 0.2412 0.0
0.77 0.3288 0.0
0.82 0.4000 0.0
0.85 0.4450 0.0 / TABLE NO. 02
The example defines two GSF tables for when gas and water are present in the input deck. In the tables the gas-water capillary pressure data has been set to zero.
| Note GSF is a compositional keyword in the commercial compositional simulator, and will therefore cause an error in the commercial black-oil simulator. Currently, both the GSF and WSF keywords can only be used with the CO2STORE and H2STORE models. |
|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|

Related keywords

Cannot be combined with
SGOF, SLGOF, SGFN

Manual source: parts/chapters/subsections/8.3/GSF.fodt