GMWSET
Recognised by the OPM Flow parserSUMMARY
This keyword is similar to the ALL keyword in the SUMMARY section, in that it results in a group of summary variables to be written out to the SUMMARY file. In this case the keyword activates the writing out of a set of data vectors that give the production and injections status of all the wells in the named groups, as well as the number of wells in the drilling queue and the number of workover events occurring within a time step for the requested groups. Both instantaneous and cumulative well counts and events for the groups are written out as tabulated in Table 11.29.
Note that GMWSET should be followed by a list of group names enclosed in quotes and therefore a terminating “/” is required to end the list of groups. A blank list requests output for all groups.
This keyword is not supported by OPM Flow but has no effect on the results so it will be ignored.
Field and Group Well Status Summary Variables
Variable
Root
Field
Group
Comment
Number of abandoned injection wells
MWIA
FMWIA
GMWIA
Number of abandoned production wells
MWPA
FMWPA
GMWPA
Number of drilling events in total
MWDT
FMWDT
GMWDT
Number of drilling events this timestep
MWDR
FMWDR
GMWDR
Number of injection wells currently flowing
MWIN
FMWIN
GMWIN
Number of injectors on group control
MWIG
FMWIG
GMWIG
Number of injectors on own reservoir volume rate limit control
MWIV
FMWIV
GMWIV
Number of injectors on own surface rate limit control
MWIS
FMWIS
GMWIS
Number of injectors on pressure control
MWIP
FMWIP
GMWIP
Number of producers controlled by own oil rate limit
MWPO
FMWPO
GMWPO
Number of producers on group control
MWPG
FMWPG
GMWPG
Number of producers on own reservoir volume rate limit control
MWPV
FMWPV
GMWPV
Number of producers on own surface rate limit control
MWPS
FMWPS
GMWPS
Number of producers on pressure control
MWPP
FMWPP
GMWPP
Number of producers using artificial lift (with ALQ > 0.0)
MWPL
FMWPL
GMWPL
Number of production wells currently flowing
MWPR
FMWPR
GMWPR
Number of unused injection wells
MWIU
FMWIU
GMWIU
Number of unused production wells
MWPU
FMWPU
GMWPU
Number of workover events in total
MWWT
FMWWT
GMWWT
Number of workover events this time step.
MWWO
FMWWO
GMWWO
Total number of injection wells
MWIT
FMWIT
GMWIT
Total number of production wells
MWPT
FMWPT
GMWPT
Notes:
Cells colored in gray with a mnemonic indicate that the summary variable is not available in OPM Flow.
Cells colored in gray with no mnemonic indicate that the summary variable is not available for this combination.
Cells colored orange show combinations that are not available in OPM Flow because the underlying feature is not available.
Table 11.29: GMWSET - Standard Field and Group Well Status Summary Variables
See also the FMWSET keyword in the SUMMARY schedule that has similar functionality but at the field level.
- Records
- No records — the keyword stands alone
Example
The first example below exports all the group standard well status variables to the SUMMARY file.
-- ==============================================================================
--
-- SUMMARY SECTION
--
-- ==============================================================================
SUMMARY
--
-- EXPORT WELL STATUS VECTORS FOR NAMED GROUPS TO FILE
--
GMWSET
/
--
-- ACTIVATE COLUMNAR SUMMARY DATA REPORTING OPTION
--
RUNSUM
--
-- ACTIVATE SUMMARY DATA RSM FILE OUTPUT OPTION
--
SEPARATE
The second example exports all the group standard well status variables for just the PLAT1 and PLT2 groups only to the SUMMARY file.
--
-- EXPORT WELL STATUS VECTORS FOR NAMED GROUPS TO FILE
--
GMWSET
‘PLAT1’ ‘PLAT2’
/
--
-- ACTIVATE COLUMNAR SUMMARY DATA REPORTING OPTION
--
RUNSUM
--
-- ACTIVATE SUMMARY DATA RSM FILE OUTPUT OPTION
--
SEPARATE
| Field and Group Well Status Summary Variables | | | | |
|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------|-------|-------|---------|
| Variable | Root | Field | Group | Comment |
| Number of abandoned injection wells | MWIA | FMWIA | GMWIA | |
| Number of abandoned production wells | MWPA | FMWPA | GMWPA | |
| Number of drilling events in total | MWDT | FMWDT | GMWDT | |
| Number of drilling events this timestep | MWDR | FMWDR | GMWDR | |
| Number of injection wells currently flowing | MWIN | FMWIN | GMWIN | |
| Number of injectors on group control | MWIG | FMWIG | GMWIG | |
| Number of injectors on own reservoir volume rate limit control | MWIV | FMWIV | GMWIV | |
| Number of injectors on own surface rate limit control | MWIS | FMWIS | GMWIS | |
| Number of injectors on pressure control | MWIP | FMWIP | GMWIP | |
| Number of producers controlled by own oil rate limit | MWPO | FMWPO | GMWPO | |
| Number of producers on group control | MWPG | FMWPG | GMWPG | |
| Number of producers on own reservoir volume rate limit control | MWPV | FMWPV | GMWPV | |
| Number of producers on own surface rate limit control | MWPS | FMWPS | GMWPS | |
| Number of producers on pressure control | MWPP | FMWPP | GMWPP | |
| Number of producers using artificial lift (with ALQ > 0.0) | MWPL | FMWPL | GMWPL | |
| Number of production wells currently flowing | MWPR | FMWPR | GMWPR | |
| Number of unused injection wells | MWIU | FMWIU | GMWIU | |
| Number of unused production wells | MWPU | FMWPU | GMWPU | |
| Number of workover events in total | MWWT | FMWWT | GMWWT | |
| Number of workover events this time step. | MWWO | FMWWO | GMWWO | |
| Total number of injection wells | MWIT | FMWIT | GMWIT | |
| Total number of production wells | MWPT | FMWPT | GMWPT | |
| Notes: Cells colored in gray with a mnemonic indicate that the summary variable is not available in OPM Flow. Cells colored in gray with no mnemonic indicate that the summary variable is not available for this combination. Cells colored orange show combinations that are not available in OPM Flow because the underlying feature is not available. | | | | |Manual source: parts/chapters/subsections/11.3/GMWSET.fodt