DATUM
Recognised by the OPM Flow parserSOLUTION
The DATUM keyword defines the datum depth for the model. This allows for all grid block potentials (depth corrected pressures) to be calculated at a common depth.
Notes:
The keyword is terminated by a “/”.
See also the DATUMR and DATUMRX keywords in the SOLUTION section that also define the datum depth for the model.
- Records
- Fixed number of records
- Record count
- 1
- Items per record
- 1
Parameters
| No. | Name | Description | Type | Dimension | Field | Metric | Lab | Default |
|---|---|---|---|---|---|---|---|---|
| 1 | DEPTHmanual: DATUM | DATUM is a single positive value that defines the datum depth for the model. | DOUBLE | Length | feet | m | cm | None |
Example
-- DATUM
-- DEPTH
-- ------
DATUM
5000.0 / DATUM DEPTH FOR REPORTING
The above example defines the datum for the model to be 5000.0Manual source: parts/chapters/subsections/10.3/DATUM.fodt