CPIFACTL
Recognised by the OPM Flow parserSCHEDULE
The CPIFACT keyword is used to define well Local Grid Refinement (“LGR”) connection transmissibility multipliers for well connections to a LGR, for when the LGR option has been invoked by the LGR keyword in the RUNSPEC section.
This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.
- Records
- One or more records, each terminated by
/ - Items per record
- 8
Parameters
| No. | Name | Description | Type |
|---|---|---|---|
| 1 | WELL | STRING | |
| 2 | MULT | UDA | |
| 3 | LGR | STRING | |
| 4 | I | INT | |
| 5 | J | INT | |
| 6 | K | INT | |
| 7 | C1 | INT | |
| 8 | C2 | INT |
Manual source: parts/chapters/subsections/12.3/CPIFACTL.fodt