COMPVE
Recognised by the OPM Flow parserSCHEDULE
The COMPVE keyword is used to re-define the well connection depths in the global grid.
This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.
- Records
- One or more records, each terminated by
/ - Items per record
- 13
Parameters
| No. | Name | Description | Type | Dimension | Default |
|---|---|---|---|---|---|
| 1 | WELL | STRING | |||
| 2 | I | INT | 0 | ||
| 3 | J | INT | 0 | ||
| 4 | K_ | INT | 0 | ||
| 5 | K_ | INT | 0 | ||
| 6 | SAT_ | INT | |||
| 7 | CVEFRAC | DOUBLE | 1 | ||
| 8 | DTOP | DOUBLE | Length | ||
| 9 | DBOT | DOUBLE | Length | ||
| 10 | FLAG | STRING | NO | ||
| 11 | S_ | DOUBLE | 0 | ||
| 12 | GTOP | DOUBLE | Length | ||
| 13 | GBOT | DOUBLE | Length |
Manual source: parts/chapters/subsections/12.3/COMPVE.fodt