COMPS

Recognised by the OPM Flow parserRUNSPEC

The COMPS keyword activates the Compositional Modeling Formulation, and declares the number of components active in the model.

OPM Flow does not currently support the general compositional modeling formulation.

Note

This keyword is only supported by OPM Flow when the two component gas-water CO2 storage model has been activated using the CO2STORE keyword and either the GASWAT or the GAS and WATER keywords in the RUNSPEC section.

Secondly, although OPM Flow parses the keyword, the simulator currently ignores the data for this keyword.

Notes:

The keyword is terminated by a “/”.

Records
Fixed number of records
Record count
1
Items per record
1

Parameters

No.NameDescriptionTypeDefault
1NUM_COMPS
manual: COMPS
A positive integer defining the number of compositional components active in the model. Only the default value of two is currently supported by OPM Flow.INT2

Example

The following example shows how to request a two component compositional modeling formulation to be used with the CO2STORE and GASWAT options.
-- ==============================================================================
--
-- RUNSPEC SECTION
--
-- ==============================================================================
RUNSPEC
--
-- ACTIVATE CO2 STORAGE IN THE MODEL (OPM FLOW CO2 STORAGE KEYWORD)
--
CO2STORE
--
-- ACTIVATE COMPOSITIONAL MODELING FORMULATION (OPM FLOW KEYWORD)
--
COMPS
2 /
--
-- ACTIVATE GAS-WATER THE MODEL (OPM FLOW KEYWORD)
--
GASWAT
| Note This keyword is only supported by OPM Flow when the two component gas-water CO2 storage model has been activated using the CO2STORE keyword and either the GASWAT or the GAS and WATER keywords in the RUNSPEC section. Secondly, although OPM Flow parses the keyword, the simulator currently ignores the data for this keyword. |
|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|

Manual source: parts/chapters/subsections/5.3/COMPS.fodt