AUTOCOAR

Recognised by the OPM Flow parserGRID

The AUTOCOAR keyword defines an area in the global grid that should be coarsen for when the AUTOREF keyword has been declared in the RUNSPEC section.

This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.

Records
One or more records, each terminated by /
Items per record
9

Parameters

No.NameDescriptionType
1I1INT
2I2INT
3J1INT
4J2INT
5K1INT
6K2INT
7NXINT
8NYINT
9NZINT