AUTOCOAR
Recognised by the OPM Flow parserGRID
The AUTOCOAR keyword defines an area in the global grid that should be coarsen for when the AUTOREF keyword has been declared in the RUNSPEC section.
This keyword is not supported by OPM Flow but would change the results if supported so the simulation will be stopped.
- Records
- One or more records, each terminated by
/ - Items per record
- 9
Parameters
| No. | Name | Description | Type |
|---|---|---|---|
| 1 | I1 | INT | |
| 2 | I2 | INT | |
| 3 | J1 | INT | |
| 4 | J2 | INT | |
| 5 | K1 | INT | |
| 6 | K2 | INT | |
| 7 | NX | INT | |
| 8 | NY | INT | |
| 9 | NZ | INT |